TITANIUM HEAT
EXCHANGERS
Titanium Tube Sheet
- Titanium Tube In
PVC Shell
- Fresh or
Saltwater Use
- Use as Heat
Exchanger or Condenser
- Compact Design
- Compression
Fittings for Titanium to Copper Connectors
- Compatible with
Refrigerant, Water or Glycol
|

HX-180-S Shown |
|
\
|
For over 15 years, Aqua Logic has been the
leader in supplying heating and chilling equipment to zoos and
public aquariums, live seafood and fish farming industries. Our
commitment to continuing product design and development allows us to
offer a wide range of heat exchangers to meet our customers varied
applications. With over 75 years of combined experience, you can be
confident that you are getting the very best. From stand alone
models to complete packages Aqua Logic has a heat exchanger to meet
your needs.
Applications:
Aqua Logic titanium tube sheet heat
exchangers were developed to maximize surface area in a very compact
package. Designed for both refrigerant to water and water to water
applications. All internal materials are non-corrosive in seawater
and will not leach toxic elements into the system water. The
internal tube sheet coil is constructed entirely of titanium tubing
and enclosed in insulated Schedule 40 PVC shell. Also available with
Schedule 80 PVC & Schedule 80 CPVC Shells. One end is flanged for
cleaning and coil inspection. Available in sizes from 7.5 hp (90,000
btus) and larger.
This style of heat exchanger can be used
in a variety of applications as listed below; when ordering this
style the series must be specified so that the unit will operate
properly for the intended application. If you are unsure of which
series to order, please, contact our sales office.
Typical applications include:
|
S Series – Chiller Barrel |
|
|
(Chiller) The heat exchanger absorbs
heat from the tank system water into the refrigerant system |
|
SHP Series – Chiller Barrel |
|
|
(Heat Pump) The heat exchanger rejects
heat into the tank system water from the refrigerant system |
|
SC Series – Condenser |
|
|
The heat exchanger rejects heat from
the refrigerant system into a water source |
|
SW Series – Water to Water |
|
|
The heat exchanger directly absorbs or
rejects heat from the tank system water into another water
source. |
Complete heat exchanger packs for
refrigerant and water to water applications are also available from
Aqua Logic.
Return to Top
Specifications:
|
S Series – Chiller Barrel |
|
Model
Number
|
Horse
Power
|
BTU
Removal
Capacity
|
Flow
(gpm)
Min/Max
|
In/Out |
Length
|
Width
|
Height
|
Estimated Weight
Lbs |
|
HX-90-S |
7.5 |
90,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
60"
|
100 |
|
HX-120-S |
10 |
120,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
66" |
110 |
|
HX-140-S |
12.5 |
140,000
|
90/180 |
3"
|
15-1/2"
|
20"
|
72"
|
120 |
|
HX-180-S
|
15 |
175,000
|
90/180
|
3"
|
15-1/2" |
20"
|
80" |
135 |
|
HX-240-S |
20 |
220,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
88"
|
150 |
|
HX-300-S
|
25 |
300,000
|
90/180
|
3"
|
34-1/2" |
20"
|
72" |
240 |
|
é |
Click on Model Number to open
.pdf Specification File |
|
SHP Series – Chiller Barrel
for Heat Pumps |
|
Model
Number
|
Horse
Power
|
BTU
Removal
Capacity
|
Flow
(gpm)
Min/Max
|
In/Out |
Length
|
Width
|
Height
|
Estimated Weight
Lbs |
|
HX-90-SHP |
7.5 |
90,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
60"
|
100 |
|
HX-120-SHP |
10 |
120,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
66" |
110 |
|
HX-140-SHP |
12.5 |
140,000
|
90/180 |
3"
|
15-1/2"
|
20"
|
72"
|
120 |
|
HX-180-SHP
|
15 |
175,000
|
90/180
|
3"
|
15-1/2" |
20"
|
80" |
135 |
|
HX-240-SHP
|
20 |
220,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
88"
|
150 |
|
HX-300-SHP
|
25 |
300,000
|
90/180
|
3"
|
34-1/2" |
20"
|
72" |
240 |
|
SC Series – Condenser |
|
Model
Number
|
Nominal
BTU
Removal
Capacity
|
|
|
HX-90-SC |
90,000
|
CONSULT AQUA
LOGIC FOR YOUR SPECIFIC APPLICATION |
|
HX-120-SC |
120,000
|
|
HX-140-SC |
140,000
|
|
HX-180-SC
|
175,000
|
|
HX-240-SC
|
220,000
|
|
HX-300-SC
|
300,000
|
BTU based on a 15˚F
∆T with 80˚F entering cooling
water and R22 refrigerant.
|
SW Series – Water to Water |
|
Model
Number
|
Nominal
BTU
Removal
Capacity
|
Flow
(gpm)
Min/Max
|
In/Out |
Length
|
Width
|
Height
|
Estimated Weight
Lbs |
|
HX-90-SW |
90,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
60"
|
100 |
|
HX-120-SW |
120,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
66" |
110 |
|
HX-140-SW |
140,000
|
90/180 |
3"
|
15-1/2"
|
20"
|
72"
|
120 |
|
HX-180-SW
|
175,000
|
90/180
|
3"
|
15-1/2" |
20"
|
80" |
135 |
|
HX-240-SW
|
220,000
|
90/180
|
3"
|
15-1/2"
|
20"
|
88"
|
150 |
|
HX-300-SW
|
300,000
|
90/180
|
3"
|
34-1/2" |
20"
|
72" |
240 |
Flow rate (GPM) & BTU removal capacity
is based on 40˚F ewt @10˚F ∆T
(cold) or 180˚F ewt @20˚F
∆T (hot) water