DX
HEAT EXCHANGER PACKS
- Titanium Heat Exchanger
- "Split
System" Chiller Applications
- Complete package
- Pre
Plumbed and Wired for Easy
Installation
- Fresh
or Saltwater Use
- Compact Design
- Digital Temperature Controller
|

HX-60-DX Shown |
|
|
Aqua Logic DX (Direct Expansion) Heat
Exchanger Packs are used in conjunction with a refrigerant
condensing unit. In a “split system” the chiller condensing unit is
located either outdoors or in an equipment room while the DX Heat
Exchanger with the necessary refrigeration components/temperature
controller is located in a separate, more convenient area for water
plumbing. The 2 components are connected via insulated copper
refrigeration lines installed by the on-site refrigeration
contractor.
Applications:
Aqua Logic’s DX Chiller Barrel Packs offer
the installer the opportunity to build a chiller package in the
field, using quality brand name components, quickly and
inexpensively. Also available for heat pumps, consult factory for
more details.
To ease installation, Aqua Logic has included a TITANIUM and PVC
chiller barrel, digital temperature controller, expansion valve,
sight glass, solenoid valve, flow switch and custom piping all
mounted on a stainless steel framework. This pre-wired and
pre-engineered system make both ordering and assembly simple. All
you need is a condensing unit of your choice or one supplied by Aqua
Logic.
Available in sizes from 1/5 hp (1,800 btus) and larger
Return to Top
Specifications:
|
Model
Number
|
Horse
Power
|
Nominal
BTU/KW |
Flow*
(gpm)
Min/Max
|
Water In/Out
FIPT
|
Refrig. In/Out
FIPT
|
Length
|
Width
|
Height
|
|
HX-2-DX
|
1/
5 |
1,800 / .5
|
6/12
|
3/4"
|
3/8" / 3/8"
|
20"
|
6-1/2"
|
20"
|
|
HX-3-DX |
1/4 |
3,000 / .8 |
8/15
|
3/4"
|
3/8" / 3/8"
|
20"
|
6-1/2" |
20"
|
|
HX-4-DX |
1/3 |
4,000 / 1.2 |
10/20
|
3/4"
|
3/8" / 3/8"
|
22"
|
6-1/2"
|
20"
|
|
HX-6-DX
|
1/2 |
6,000 / 1.8 |
12/25
|
1-1/2"
|
3/8" / 1/2"
|
23"
|
6-1/2" |
20"
|
|
HX-9-DX |
3/4 |
9,5000 / 2.6 |
20/35
|
1-1/2"
|
3/8" / 1/2"
|
30"
|
6-1/2"
|
20"
|
|
HX-12-DX |
1
|
12,000 / 3.5
|
25/40
|
1-1/2"
|
3/8" / 5/8"
|
33"
|
6-1/2" |
20"
|
|
HX-24-DX |
2 |
24,000 / 7
|
20/40
|
2"
|
3/8" / 5/8"
|
28"
|
14"
|
26"
|
|
HX-36-DX |
3 |
36,000 / 10.5 |
20/40
|
2"
|
3/8" / 5/8"
|
35"
|
14" |
26"
|
|
HX-48-DX |
4 |
48,000 / 14 |
30/60
|
2"
|
3/8" / 1-1/8"
|
43"
|
14"
|
26"
|
|
HX-60-DX |
5 |
60,000 / 17.5 |
30/60
|
2"
|
3/8" / 1-1/8"
|
50"
|
14" |
26"
|
|
HX-90-DX |
7.5 |
96,000 / 28 |
90/180
|
3"
|
1/2"
/ 1-3/8"
|
20"
|
20"
|
50"
|
|
HX-120-DX |
10 |
120,000 / 35 |
90/180
|
3"
|
1/2"
/ 1-3/8"
|
20"
|
20" |
60"
|
|
HX-150DX |
12.5 |
150,000 / 44 |
90/180
|
3"
|
2
at 3/8" / 1-3/8"
|
20"
|
20"
|
66"
|
|
HX-180-DX
|
15 |
175,000 / 51.2 |
90/180
|
3"
|
5/8"
/ 1-5/8" |
20"
|
20" |
72"
|
|
HX-240-DX
|
20 |
223,000 / 65.3 |
90/180
|
3"
|
2
at
1/2" / 1-3/8" |
20"
|
20"
|
88"
|
|
HX-300-DX
|
25 |
300,000 /
87.8 |
90/180
|
3"
|
7/8"
/ 2-1/8" |
20"
|
20" |
72"
|
|
HX-360-DX
|
30 |
360,000 /
105 |
90/180
|
3"
|
2
at
7/8" / 2-1/8" |
20"
|
20"
|
88"
|
|
é |
Click on Model Number to open
.pdf Specification File |
*Minimum flow rate at 65F and above.
At 65F and below 120GPM minimum flow rate.
HX-3-DX - 6-DX 24V Dimentions
HX-2-DX - 12-DX 24V Details
|
Model
Number
|
Horse
Power
|
Nominal
BTU/KW |
Flow*
(gpm)
Min/Max
|
Water In/Out
FIPT
|
Refrig. In/Out
FIPT
|
Length
|
Width
|
Height
|
|
HX-24-
DX-HP |
2 |
24,000 / 7 |
20/40 |
2"
|
3/8" / 5/8"
|
28"
|
14"
|
26"
|
|
HX-36-
DX-HP |
3 |
36,000 / 10.5 |
20/40 |
2"
|
3/8" / 5/8"
|
35"
|
14" |
26"
|
|
HX-48-
DX-HP |
4 |
48,000 / 14 |
30/60 |
2"
|
3/8" / 1-1/8"
|
43"
|
14"
|
26"
|
|
HX-60-
DX-HP
|
5 |
60,000 / 17.5 |
30/60 |
2"
|
3/8" / 1-1/8"
|
50"
|
14" |
26"
|
|
é |
Click on Model Number to open
.pdf Specification File |
|
Model
Number
|
Horse
Power
|
Nominal
BTU/KW |
Flow*
(gpm)
Min/Max
|
Water In/Out
FIPT
|
Refrig. In/Out
FIPT
|
Length
|
Width
|
Height
|
|
HX-120-DXD |
10 |
120,000 / 35 |
90/180
|
3"
|
2
at
3/8" / 1-1/8"
|
24"
|
18"
|
60" |
|
HX-150-DXD |
12.5 |
140,000 / 41 |
90/180
|
3"
|
2
at
3/8" / 1-1/8"
|
24"
|
18" |
60" |
|
HX-180-DXD |
15 |
175,000 / 51.2 |
90/180
|
3"
|
2
at
1/2" / 1-3/8"
|
24"
|
18"
|
72" |
|
HX-240-DXD
|
20 |
220,000 / 64.4 |
90/180
|
3"
|
2
at
1/2" / 1-3/8"
|
24"
|
18" |
88" |
|
é |
Click on Model Number to open
.pdf Specification File |
*Minimum flow rate at 65F and above.
At 65F and below 120GPM minimum flow rate.
|
Model
Number
|
Horse
Power
|
Nominal
BTU/KW |
Flow*
(gpm)
Min/Max
|
Water In/Out
FIPT
|
Refrig. In/Out
FIPT
|
Length
|
Width
|
Height
|
|
HX-120-DXD-HP |
10 |
120,000 / 35 |
90/180
|
3"
|
2
at
3/8" / 1-1/8"
|
24"
|
24"
|
60" |
|
HX-150-DXD-HP |
12.5 |
140,000 / 41 |
90/180
|
3"
|
2
at
3/8" / 1-1/8"
|
24"
|
24" |
60" |
|
HX-180-DXD-HP |
15 |
175,000 / 51.2 |
90/180
|
3"
|
2
at
1/2" / 1-3/8"
|
24"
|
24"
|
72" |
|
HX-240-DXD-HP
|
20 |
220,000 / 64.4 |
90/180
|
3"
|
2
at
1/2" / 1-3/8"
|
24"
|
24" |
88" |
|
é |
Click on Model Number to open
.pdf Specification File |
*Minimum flow rate at 65F and above.
At 65F and below 120GPM minimum flow rate.

Return to Top
Warranty:
Heat Exchanger and Heat Exchanger
Packs Warranty
Thermostats
| Flow Switch |
Water Pumps |
|