Aqua Logic - Heat Exchangers
     

 

 
   

 

   

DX HEAT EXCHANGER PACKS
 

  • Titanium Heat Exchanger
  • "Split System" Chiller Applications
  • Complete package
  • Pre Plumbed and Wired for  Easy Installation
  • Fresh or Saltwater Use
  • Compact Design
  • Digital Temperature Controller

HX-60-DX Shown

 

Aqua Logic DX (Direct Expansion) Heat Exchanger Packs are used in conjunction with a refrigerant condensing unit. In a “split system” the chiller condensing unit is located either outdoors or in an equipment room while the DX Heat Exchanger with the necessary refrigeration components/temperature controller is located in a separate, more convenient area for water plumbing. The 2 components are connected via insulated copper refrigeration lines installed by the on-site refrigeration contractor.

Applications:

Aqua Logic’s DX Chiller Barrel Packs offer the installer the opportunity to build a chiller package in the field, using quality brand name components, quickly and inexpensively. Also available for heat pumps, consult factory for more details.

To ease installation, Aqua Logic has included a TITANIUM and PVC chiller barrel, digital temperature controller, expansion valve, sight glass, solenoid valve, flow switch and custom piping all mounted on a stainless steel framework. This pre-wired and pre-engineered system make both ordering and assembly simple. All you need is a condensing unit of your choice or one supplied by Aqua Logic.

Available in sizes from 1/5 hp (1,800 btus) and larger
 

Return to Top

Specifications:
 

Model
Number

Horse
Power

Nominal BTU/KW

Flow*
(gpm)
Min/Max

Water In/Out
FIPT

Refrig. In/Out
FIPT

Length

Width

Height

HX-2-DX

1/ 5

1,800 / .5

6/12

3/4"

3/8" / 3/8"

20"

6-1/2"

20"

HX-3-DX

1/4

3,000 / .8

8/15

3/4"

3/8" / 3/8"

20"

6-1/2"

20"

HX-4-DX

1/3

4,000 / 1.2

10/20

3/4"

3/8" / 3/8"

22"

6-1/2"

20"

HX-6-DX

1/2

6,000 / 1.8

12/25

1-1/2"

3/8" / 1/2"

23"

6-1/2"

20"

HX-9-DX

3/4

9,5000 / 2.6

20/35

1-1/2"

3/8" / 1/2"

30"

6-1/2"

20"

HX-12-DX

1

12,000 / 3.5

25/40

1-1/2"

3/8" / 5/8"

33"

6-1/2"

20"

HX-24-DX

2

24,000 / 7

20/40

2"

3/8" / 5/8"

28"

14"

26"

HX-36-DX

3

36,000 / 10.5

20/40

2"

3/8" / 5/8"

35"

14"

26"

HX-48-DX

4

48,000 / 14

30/60 

2"

3/8" / 1-1/8"

43"

14"

26"

HX-60-DX

5

60,000 / 17.5

30/60 

2"

3/8" / 1-1/8"

50"

14"

26"

HX-90-DX

7.5

96,000 / 28

90/180 

3" 1/2" / 1-3/8" 20"

20"

50"

HX-120-DX

10

120,000 / 35

90/180

3" 1/2" / 1-3/8" 20"

20"

60"

HX-150DX

12.5 150,000 / 44 90/180 3" 2 at 3/8" / 1-3/8" 20"

20"

66"

HX-180-DX

15 175,000 / 51.2 90/180 3" 5/8" / 1-5/8" 20"

20"

72"

HX-240-DX

20 223,000 / 65.3 90/180

3"

2 at 1/2" / 1-3/8" 20"

20"

88"

HX-300-DX

25 300,000 / 87.8 90/180 3" 7/8" / 2-1/8" 20"

20"

72"

HX-360-DX

30 360,000 / 105 90/180

3"

2 at 7/8" / 2-1/8" 20"

20"

88"

 

é

 

Click on Model Number to open .pdf  Specification File

*Minimum flow rate at 65F and above.  At 65F and below 120GPM minimum flow rate.

HX-3-DX  -  6-DX  24V Dimentions

HX-2-DX  -  12-DX 24V Details

Model
Number

Horse
Power

Nominal BTU/KW

Flow*
(gpm)
Min/Max

Water In/Out
FIPT

Refrig. In/Out
FIPT

Length

Width

Height

HX-24-

DX-HP

2

24,000 / 7

20/40 2"

3/8" / 5/8"

28"

14"

26"

HX-36-

DX-HP

3

36,000 / 10.5

20/40

2"

3/8" / 5/8"

35"

14"

26"

HX-48-

DX-HP

4

48,000 / 14

30/60 2"

3/8" / 1-1/8"

43"

14"

26"

HX-60-

DX-HP

5 60,000 / 17.5 30/60 2"

3/8" / 1-1/8"

50"

14"

26"

 

é

 

Click on Model Number to open .pdf  Specification File

 

 

Model
Number

Horse
Power

Nominal BTU/KW

Flow*
(gpm)
Min/Max

Water In/Out
FIPT

Refrig. In/Out
FIPT

Length

Width

Height

HX-120-DXD

10 120,000 / 35 90/180 3" 2 at 3/8" / 1-1/8" 24"

18"

60"

HX-150-DXD

12.5

140,000 / 41

90/180

3" 2 at 3/8" / 1-1/8" 24"

18"

60"

HX-180-DXD

15 175,000 / 51.2 90/180 3" 2 at 1/2" / 1-3/8" 24"

18"

72"

HX-240-DXD

20 220,000 / 64.4 90/180 3" 2 at 1/2" / 1-3/8" 24"

18"

88"

 

é

 

Click on Model Number to open .pdf  Specification File

*Minimum flow rate at 65F and above.  At 65F and below 120GPM minimum flow rate.

 

Model
Number

Horse
Power

Nominal BTU/KW

Flow*
(gpm)
Min/Max

Water In/Out
FIPT

Refrig. In/Out
FIPT

Length

Width

Height

HX-120-DXD-HP

10 120,000 / 35 90/180 3" 2 at 3/8" / 1-1/8" 24"

24"

60"

HX-150-DXD-HP

12.5

140,000 / 41

90/180

3" 2 at 3/8" / 1-1/8" 24"

24"

60"

HX-180-DXD-HP

15 175,000 / 51.2 90/180 3" 2 at 1/2" / 1-3/8" 24"

24"

72"

HX-240-DXD-HP

20 220,000 / 64.4 90/180 3" 2 at 1/2" / 1-3/8" 24"

24"

88"

 

é

 

Click on Model Number to open .pdf  Specification File

*Minimum flow rate at 65F and above.  At 65F and below 120GPM minimum flow rate.

 

Return to Top

Warranty:

Heat Exchanger and Heat Exchanger Packs Warranty

Thermostats  |  Flow Switch  |  Water Pumps  

 


PRODUCT LITERATURE
APPLICATIONS
SPECIFICATIONS
GUIDELINES
SIZING
MANUALS

WARRANTY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

Home  |  About Aqua Logic  |  Manuals & FAQs  |  Contact Us  |  Aquanetics Parts  |  Site Map

8268 Clairemont Mesa Blvd. Suite #302  |  San Diego  |  California  |  92111    858.292.4773  |  fax 858.279.0537
 

Water Chillers  |  Cold Loop Systems  |  Custom Fabrication  |  Filters  |  Flow Switches  |  Heat Exchangers  |  Heaters
Heat Pumps  |  Life Support Systems  |  UV Sterilizers  |  Tank Systems  |  Temperature Controllers  |  Water Pumps
Home & Office Aquariums  |  Tank Systems  |  Public Installations  |  Aquaculture & Research  |  Custom & OEM
For the Media  |  Privacy Policy  |  Terms of Use

Copyright © 2007, Aqua Logic, Inc.  All rights reserved.