Water Chillers by Aqua Logic, Inc.
     

 

 
   

 

   

DELTA STAR®
AIR COOLED

1/5HP - 1 1/2HP

  • In-Line Tube In Shell Heat Exchanger
  • Fresh or Saltwater Use
  • Compact Design
  • Quiet Operation
  • Black ABS Cover
  • Remote Electronic Temperature Controller
  • Ozone Friendly Refrigerant (134A)


Mouse Over to Remove Cover

 

 

WARRANTY:  2 YEAR LIMITED WARRANTY FROM DATE OF PURCHASE

 
 

DELTA STAR & TRIMLINE DELTA STAR PRODUCT LITERATURE


Aqua Logic’s Delta Star in line TITANIUM water chillers were first introduced to the aquatic market in 1989. Known for their quality craftsmanship and exceptional performance they quickly became the industry standard that all other brands have tried to achieve. For over 15 years this same attention to quality and performance still goes into every unit we manufacture.

TITANIUM is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems. The Delta Star is built with an oversized helical titanium coil in the heat exchanger to maximize BTU transfer efficiency. The quite, internal, spring mounted hermetic motor/compressor provides years of reliable service. Their low profile and compact design allows for easy placement in tight places.

Each unit comes with a Black ABS plastic cover. A pump is required with Delta Star chillers to move water thru the heat exchanger. Please see section below for recommended pump selection chart.

Applications:

Aqua Logic manufactures chillers for a wide variety of applications. Since “one chiller does not fit all” chillers are designed and build for specific uses. For example Marine Reef Tanks are typically maintained at a constant temperature of 76˚ - 78˚F while bait tanks are cooler, around 50˚ - 55˚F. Research applications may require the chiller to maintain a wide range of temperatures as low as 35˚F during some portion of the experiment and as high as 80˚F during other times. Each of the scenarios requires the chiller to be manufactured with different parts so they operate at their maximum efficiency.

Our “standard” units (1/5-1/2 hp) are for applications where the temperature to be maintained is in the range of 65˚ - 80˚F such as reef tanks and warm water fish exhibits. The cool water units (option A with coldwater cap tube) are designed for a temperature range of 50˚ - 65˚F for bait fish and temperate fish exhibits. For those applications where the unit will need to maintain a very cold temperature, such as lobster tanks, cold water fish exhibits or research applications then our Option B with TXV would be required.

Our Standard and Option A units are manufactured with a capillary tube of a size and length that allows a fixed amount of refrigerant to enter the titanium coil of the heat exchanger. This amount of refrigerant does not need to change since the water temperature being maintained remains relatively constant. These units are less expensive then the Option B units. Option B chillers have a thermal expansion valve that constantly regulates the amount of refrigerant going to the heat exchanger based on the temperature of the water that it needs to maintain. Colder water requires more refrigerant flow and warmer water requires less.

All our Delta Star chillers 3/4hp and larger chillers come with the option B feature.

You need to keep the above in mind when ordering your chiller. If you need a chiller for your lobster tank the chiller from aquarium store, catalog, or online retailer may not work for you.

If you have any questions or not sure which chiller is right for you contact our office for help with your specific application.

Return to Top

Specifications:

Model
Number

Horse
Power

BTUH
Removal
Capacity

Volts/
Phase

Amps

Flow
(gpm)
Min/Max

In/Out
FIPT

(in)

Length
(in)

Width
(in)

Height
(in)

Weight
(lbs)

DS-2

1/5

1,810

115

3.4

6/12

3/4"

19"

12"

11"

48 lbs.

DS-3

1/4

3,080

115

5.4

8/15

3/4"

19"

12"

11"

60 lbs.

DS-4

1/3

4,050

115

7.2

10/20

3/4"

22 1/2"

13"

11"

66 lbs.

DS-5

1/2

6,000

115

9.5

12/25

1-1/2"

24"

15 1/2"

13"

100 lbs.

DS-6

1/2

6,000

230

4.8

12/25

1-1/2"

24"

15 1/2"

13"

100 lbs.

DS-7

3/4

9,500

115

13.0

15/30

1-1/2"

25"

21"

15"

112 lbs.

DS-8

3/4

9,500

230

7.0

15/30

1-1/2"

25"

21"

15"

112 lbs.

DS-9

1

12,000

230

7.2

20/35

1-1/2"

27"

24"

15"

117 lbs.

DS-10*

1.5

21,000

230

10.5

25/40

1-1/2"

31"

26"

19"

147 lbs.

 

é

 

Click on Chiller Model Number to open .pdf  Specification File

*Uses R-22 refrigerant. Water must be pumped through the chiller. Pump is not included.

Delta Star - Water Cooled Dimensions

Return to Top

Guidelines:

When you install your chiller properly you will get many years of dependable service. One of the most important things to keep in mind when you position your chiller is air flow. Fresh air flow should never be restricted to the condenser (looks like a car radiator) and the hot air discharged must not be restricted when it leaves the unit. As air passes thru condenser, over time dirt and dust may accumulate so it should be placed where you have easy access to it for periodic cleaning.

Chillers should not be placed in a confined space such as a cabinet or closet as temperatures can easily get over 90˚F thus reducing the efficiency of the chiller and possible failure. Also if there are open sumps heat from the chiller will go right back in the water and could cause your tank to heat up. The moist salty air will also cause corrosion of the condenser and other external parts resulting in failure of the chiller.

Delta Star inline chillers require a pump to move water thru the heat exchanger and Cyclone drop in chillers require water passing by the coil at all times. Correct water flow rates are critical for chillers to operate properly. Refer to the chiller flow rate and pump selection chart to select the best pump for your chiller. Always use an external pump as submersible pumps add heat to the water.

Return to Top

Sizing:

Many factors will have an influence when determining the size water chiller required for a particular application. While standard Btu calculations will give you a good starting point for sizing, many environmental and system design parameters must be considered. While sizing charts can be helpful, one chart DOES NOT work for all chiller installations.

Sizing charts for marine reef tanks (under 1500 gallons) are based on “typical” setups using the common life support equipment (LSS), such as pumps, filters, and lighting. However, some tanks have more pumps or higher wattage lighting then what might be considered “normal”. This must be considered when looking at a sizing chart. The sizing chart we provide for reef aquariums is based on many years of experience and a typical tank setup.

The sizing charts for aquaculture system, large public aquarium tanks and other fish holding systems are different then that of the marine reef tank. These systems may contain just one large tank or multiple tanks, located indoors in a controlled environment or outdoors in direct sunlight, and every situation in-between. These systems may require more or less hp per gallon then reef aquariums. Adding insulation and thermal pane viewing windows will decrease the amount hp per gallon required.

For hydroponic applications nutrient solutions need to be cooled. Although the volumes may seem small it is spread out over a large area and there is a tremendous amount of heat input from either grow lights or natural sunlight. This heat input is greatest when plants are young but as they grow and start shading their growing trays the heat input decreases. Due to the numerous variety of set ups these systems can be difficult to size.

We provide a questionnaire that you can fill out and return to us for help in sizing a chiller for your particular application. The more information you provide the better.

As always we have a staff of technicians that are ready to help answer any technical questions you may have.

 

Chiller Selection Charts

|

Sizing Reef Aquariums 

System Questionnaire

|

Circulation Pump Selection Chart

Return to Top

Manual:

Installation and Maintenance Manual for Delta Star® In-Line Chiller & Cyclone® Water Chiller

ALI Quick Install - CyclonePro & DeltaStarPro

Thermostats  |  Flow Switch  |  Water Pumps                

 


PRODUCT LITERATURE
APPLICATIONS
SPECIFICATIONS
GUIDELINES
SIZING
MANUALS

WARRANTY

THERMOSTATS
WATER PUMPS
FLOW SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

Home  |  About Aqua Logic  |  Manuals & FAQs  |  Contact Us  |  Aquanetics Parts  |  Site Map

8268 Clairemont Mesa Blvd. Suite #302  |  San Diego  |  California  |  92111    858.292.4773  |  fax 858.279.0537
 

Water Chillers  |  Cold Loop Systems  |  Custom Fabrication  |  Filters  |  Flow Switches  |  Heat Exchangers  |  Heaters
Heat Pumps  |  Life Support Systems  |  UV Sterilizers  |  Tank Systems  |  Temperature Controllers  |  Water Pumps
Home & Office Aquariums  |  Tank Systems  |  Public Installations  |  Aquaculture & Research  |  Custom & OEM
For the Media  |  Privacy Policy  |  Terms of Use

Copyright © 2007, Aqua Logic, Inc.  All rights reserved.